Waferpedia

Varian

Kestrel II 750

Kestrel II 750 — Inventory photo
Fig. 01Kestrel II 750Inventory photo[1]

Wafer size

10 Site Disk, 10 Wafer per Batch

Power

Power Supply Interface (PSI) Controller[1]

Vacuum

Source Vacuum Controller[1]

Gas delivery

Fully Automated Gas Box, 4 Gas Modules[1]

Optics

Included[3]

What it is

The Varian Kestrel II 750 is an ion implantation system for semiconductor wafer doping.[3]

How it works

General reference — not yet source-verified

Ion implanters accelerate a beam of ionized dopant atoms and direct that beam into a semiconductor wafer.

Where it fits in the process flow

General reference — not yet source-verified

Ion implantation is a doping step in semiconductor fabrication.

Implantation follows pattern definition steps and precedes annealing that activates dopants and repairs crystal damage.

Applications

The Kestrel II 750 is used for semiconductor wafer doping by ion implantation.[3]

What do the numbers mean?

Power & electrical4

Power Supply Interface (PSI) Controller[1]
Accurate?
Voltage
30 kV Terminal PS[1]
Accurate?
Voltage
60 kV Tube Lens PS[1]
Accurate?
Power Supply Interface (PSI) Controller
Included[3]
Accurate?

Vacuum & pumping2

Source Vacuum Controller[1]
Accurate?
Source Vacuum Controller
Included[3]
Accurate?

Wafer handling4

Wafer size
10 Site Disk, 10 Wafer per Batch[3]
Accurate?
Wafer Size
8 inch[2]
Accurate?
Batch Size
10 Wafers per Batch[1]
Accurate?
Wafer size
Wafer Lifter Assy[1]
Accurate?

Gas & chemistry4

Fully Automated Gas Box, 4 Gas Modules[1]
Accurate?
Gas Modules
4 Gas Modules[1]
Accurate?
Gases
Argon (factory inlet), PH3 SDS, AsH3 SDS, BF3 SDS[1]
Accurate?
Gas box
Fully Automated Gas Box, 4 Gas Modules[1]
Accurate?

Optics & imaging1

60 kV Tube Lens PS
Included[3]
Accurate?

Control & software4

Software Version 6.41[1]
Accurate?
Manipulator Controller[1]
Accurate?
Software Version
6.41[3]
Accurate?
Manipulator Controller
Included[3]
Accurate?

Configuration & options19

High current[2]
Accurate?
Energy Range
10 - 3750 kV[1]
Accurate?
Automatic Handling system[1]
Accurate?
Argon (factory inlet)[1]
Accurate?
PH3 SDS[1]
Accurate?
AsH3 SDS[1]
Accurate?
BF3 SDS[1]
Accurate?
On Board Argon Option Installed (Semi Automated Filling of Stripper Reservoirs[1]
Accurate?
Spare Parts:[1]
Accurate?
Suppression PS[1]
Accurate?
Arc Sense PS[1]
Accurate?
Analyser Magnet PS[1]
Accurate?
Accel Driver Assy[1]
Accurate?
Disk Sites
10 Site Disk[1]
Accurate?
Automatic Handling
Yes[1]
Accurate?
High Current
Yes[3]
Accurate?
30 kV Terminal PS
Included[3]
Accurate?
Category
Ion Implantation[3]
Accurate?
Handling system
Automatic Handling system[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • ConfigurationFully Automated Gas Box, 4 Gas Modules[1]
  • ConfigurationPower Supply Interface (PSI) Controller[1]
  • ConfigurationSource Vacuum Controller[1]
  • Voltage30 kV Terminal PS[1]
  • Voltage60 kV Tube Lens PS[1]
  • Gas Modules4 Gas Modules[1]
  • GasesArgon (factory inlet), PH3 SDS, AsH3 SDS, BF3 SDS[1]
  • Power Supply Interface (PSI) ControllerIncluded[3]
  • Source Vacuum ControllerIncluded[3]
  • Gas boxFully Automated Gas Box, 4 Gas Modules[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the energy range of the Varian Kestrel II 750?

The energy range is 10 to 3750 kV.[1][3]

Is the Kestrel II 750 a high-current implanter?

Yes, it is a high-current ion implanter.[2][3]

What is the batch size for the Kestrel II 750?

The system uses a 10-site disk and processes 10 wafers per batch.[1][3]

Not publicly documented

The following facts about the Kestrel II 750 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Kestrel II 750 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the Kestrel II 750 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the Kestrel II 750 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Kestrel II 750 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Kestrel II 750 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (4)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]inventory listing
  3. [3]waferpedia.com — waferpedia.comwaferpedia.com
  4. [4]Equipment inventory listing
Was this page accurate?

Last updated Oct 4, 2026.

Compare with similar tools