Waferpedia

Nikon

Labophot 2

Metrology & InspectionNikon Labophot 2 family
Research Quality: 40% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Nikon Labophot 2 is a modular microscope utilizing the Nikon CF optical system. The Labophot 2 is available with either a forward or rear facing quintuple nosepiece and features a 6-volt, 20-watt Köhler illumination system with a halogen lamp and variable control.[1]

Nikon logo
Fig. — Manufacturer logo, not a photo of this toolWikimedia Commons (see file page for license)

Power

6V-30W halogen bulb (Philips special type)[3]

Optics

Nikon CF optical system[1]

What it is

General reference — not yet source-verified

The Nikon Labophot 2 is a microscope used for laboratory inspection and metrology work.

How it works

The Nikon Labophot 2 uses a modular microscope layout with a stand, eyepiece tube, revolving nosepiece, stage, condenser, and adjustable illumination.[3][1][4][5]

Where it fits in the process flow

General reference — not yet source-verified

A microscope of this class sits in inspection, characterization, and bench-level measurement workflows rather than in wafer fabrication steps.

Applications

General reference — not yet source-verified

A microscope of this class is used to examine samples, structures, and surface features that require direct visual inspection at high magnification.

What do the numbers mean?

Power & electrical6

Illumination
6V-20W halogen lamp with Köhler illumination and variable control potentiometer[1]
Accurate?
Lamp (alternative)
6V-30W halogen bulb (Philips special type)[3]
Accurate?
Illumination Type
6V-30W halogen bulb (special Philips type); Köhler illumination[3]
Accurate?
Lamp Power
6V, 20W (standard) or 6V-30W (replacement bulb)[1]
Accurate?
Lamp house
100 watt mercury lamphouse[5]
Accurate?
Power supply
100 watt mercury power supply[5]
Accurate?

Wafer handling1

Filter Holder
Quick-change filter holder (ND filter cassette, filter receptacle)[3]
Accurate?

Optics & imaging13

Optical System
Nikon CF optical system[1]
Accurate?
Objectives (standard)
E Plan 4/0.1 160/-, E Plan 10/0.25 LWD, E Plan 40/0.65 160/0.17 in a quintuple nosepiece[1]
Accurate?
Objectives (standard configuration)
E Plan 4/0.1 160/-, E Plan 10/0.25 LWD, E Plan 40/0.65 160/0.17[1]
Accurate?
Objective Magnifications Available
4X, 10X, 20X, 40X, 50X, 100X[4]
Accurate?
Objectives
Five objective lenses: 100X, 50X, 40X, 10X, and 4X[4]
Accurate?
Illumination
Light source with filters and a collimator[4]
Accurate?
Head
Trinocular head with C-mount camera coupler[5]
Accurate?
Fluorescence illuminator
Fluorescence vertical illuminator[5]
Accurate?
Objectives
Plan 4X phase contrast objective[5]
Accurate?
Objectives
Plan 10X phase contrast objective[5]
Accurate?
Objectives
Plan 20X phase contrast objective[5]
Accurate?
Objectives
40X phase contrast objective[5]
Accurate?
Objectives
Fluor 40X brightfield objective with correction collar[5]
Accurate?

Configuration & options22

Polarizing[2]
Accurate?
Focusing (coarse)
12mm per rotation[3]
Accurate?
Focusing (fine)
0.1mm per rotation, each graduation 1 micron[3]
Accurate?
Eyepieces (standard)
Two CFWN 10x/20[1]
Accurate?
Stage (standard)
Mechanical slide stage[1]
Accurate?
Condenser (standard)
Abbe 1.25 brightfield condenser[1]
Accurate?
Eyepiece tube inclination
30 degrees (Seidentoph design)[1]
Accurate?
Phase Contrast
Can use Green interference filter (GIF) for phase difference microscopy[3]
Accurate?
Nosepiece
Quintuple nosepiece; forward or rear facing[1]
Accurate?
Eyepieces (Oculars)
CFWN 10x/20 eyepieces (standard); 10X widefield adjustable eyepieces[1]
Accurate?
Stage
Mechanical rectangular or circular rotatable with six minute vernier gradations; graded adjustable stage[1]
Accurate?
Focusing Movement
Coarse focus knob moves stage 12mm per rotation; fine focus knob moves stage 0.1mm per rotation (1 micron per graduation)[3]
Accurate?
Condenser Centering
Centering screws provided; quick-change condenser mount without re-adjusting centering screws[1]
Accurate?
Make
Nikon[2]
Accurate?
Model
Labophot 2[2]
Accurate?
Microscope type
Polarizing microscope[2]
Accurate?
Microscope type
Binocular microscope[4]
Accurate?
Ocular lenses
10X ocular lenses[4]
Accurate?
Stage
Graded, adjustable stage[4]
Accurate?
Microscope type
Fluorescence and phase contrast trinocular microscope[5]
Accurate?
Eyepieces
10X widefield adjustable eyepieces[5]
Accurate?
Phase contrast condenser
Turret style phase contrast condenser with phase 1, 2, 3, darkfield, and brightfield stops[5]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Illumination6V-20W halogen lamp with Köhler illumination and variable control potentiometer[1]
  • Lamp (alternative)6V-30W halogen bulb (Philips special type)[3]
  • Illumination Type6V-30W halogen bulb (special Philips type); Köhler illumination[3]
  • Lamp Power6V, 20W (standard) or 6V-30W (replacement bulb)[1]
  • Lamp house100 watt mercury lamphouse[5]
  • Power supply100 watt mercury power supply[5]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What magnification range is typical for microscopes of this class?General reference — not yet source-verified

Optical microscopes in this class typically offer a range of objective lenses that provide from low to high magnification, enabling both wide-field overviews and high-resolution detail inspection. The exact magnification depends on the objectives and eyepieces selected.

Can this type of microscope be used for automated measurements?General reference — not yet source-verified

Yes, many systems in this class can be equipped with motorized stages and automated measurement software to perform repetitive tasks such as critical-dimension measurement or defect counting. Manual operation remains common for ad-hoc inspection.

What illumination modes are available on such microscopes?General reference — not yet source-verified

Common illumination modes include brightfield for general surface inspection, darkfield for detecting scratches and particles, and sometimes differential interference contrast for enhancing edge features. The specific modes depend on the optical configuration.

Not publicly documented

The following facts about the Labophot 2 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Labophot 2 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the Labophot 2 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the Labophot 2 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Labophot 2 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Labophot 2 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (5)Every fact above is drawn from these public sources
  1. [1]labwrench.com — labwrench.comlabwrench.com
  2. [2]inventory listing
  3. [3]manualslib.com — manualslib.commanualslib.com
  4. [4]medicalinst.com — medicalinst.commedicalinst.com
  5. [5]spachoptics.com — spachoptics.comspachoptics.com
Was this page accurate?

Last updated Oct 4, 2026.

Compare with similar tools

View all →