The Glenbrook JewelBox-100T is an X-ray inspection system. The Glenbrook JewelBox-100T supports PCB X-ray analysis. The Glenbrook JewelBox-100T offers five-axis control of the inspected product, including 360° rotation and tilt.[1][2][3][4]

JewelBox-100T — web.archive.org
Fig. 01JewelBox-100Tweb.archive.org[1]

Power

120v/60 hz or 220v/50 hz[2]

Optics

500 line pairs/mm[2]

What it is

The Glenbrook JewelBox-100T is an X-ray inspection system in the metrology and inspection category. The JewelBox-100T is part of the JewelBox series and is used for PCB X-ray analysis.[2][5]

How it works

The JewelBox-100T uses microfocus X-ray imaging to produce high-magnification images with gray-scale accuracy. The JewelBox-100T uses a 100 kV X-ray tube with a 5 micron focal spot, and the tube replaces a 90 kV tube with a 5 to 7 micron focal spot.[2]

Where it fits in the process flow

General reference — not yet source-verified

The JewelBox-100T fits in inspection and failure-analysis workflows after assembly steps and before or during disposition decisions for electronic hardware. The JewelBox-100T is used to examine internal construction in assemblies where destructive cross-sectioning is not desired.

Applications

The JewelBox-100T is used where internal solder, bond, and attachment features must be inspected through opaque package materials. The JewelBox-100T supports inspection of both high-density and low-density devices.[2]

  • PCB X-ray analysis

Why won't it start?

Documented failure modes, common issues, and field considerations.

  • The JewelBox-100T is described as avoiding aberrations of voltage blooming and pincushioning.

What do the numbers mean?

Power & electrical3

Operating voltage
120v/60 hz or 220v/50 hz[2]
Accurate?
Anode voltage
100 kv[2]
Accurate?
Anode current
100 μAmps (adjustable)[2]
Accurate?

Optics & imaging2

Resolution
500 line pairs/mm[2]
Accurate?
Magnification
variable from 7X up to 2000X[2]
Accurate?

Control & software2

Computer console dimensions
28 3/8”W x 29 3/4”D x 36 3/4”H[2]
Accurate?
Image processing software
GTI-50 Image Processing Software and USB frame grabber[2]
Accurate?

Dimensions & facilities2

Nominal exterior dimensions
35 1/8”W x 43 1/8”D x 72 3/4”H[2]
Accurate?
Inspection compartment dimensions
28 1/2”W x 30”D x 23 3/4”H[2]
Accurate?

Configuration & options5

Product line
JewelBox Series[1]
Accurate?
Model
JewelBox-100T[1]
Accurate?
Focal spot size
5 micron[2]
Accurate?
Focal spot to image plane distance
9-12 inches (factory preset)[2]
Accurate?
Manipulator
five-axis joystick positioner[2]
Accurate?

Vintage & configurations

  1. 2023Referenced in PCB X-ray analysis news item[1]

    The JewelBox-100T is referenced in an October 2023 news item about PCB X-ray analysis.

Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Operating voltage120v/60 hz or 220v/50 hz[2]
  • Anode voltage100 kv[2]
  • Anode current100 μAmps (adjustable)[2]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What magnification range does the JewelBox-100T provide?

The JewelBox-100T provides variable magnification from 7X to 2000X.[2]

What X-ray source does the JewelBox-100T use?

The JewelBox-100T uses a 100 kV X-ray tube with a 5 micron focal spot.[2]

What motion control does the JewelBox-100T provide?

The JewelBox-100T offers five-axis control of the inspected product, including 360° rotation and tilt.[2]

Not publicly documented

The following facts about the JewelBox-100T are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented variants, configuration options, or revision breakpoints of the JewelBox-100T are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the JewelBox-100T are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • The process node or technology generation of the JewelBox-100T is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the JewelBox-100T are on record.

    Answerable by: an OEM parts catalog or a service engineer

  • No publicly hosted manuals, SOPs, or datasheets for the JewelBox-100T are on record.

    Answerable by: university cleanroom staff or an OEM application specialist

Sources & citations

Sources (5)Every fact above is drawn from these public sources
  1. [1]web.archive.org — web.archive.orgweb.archive.org
  2. [2]glenbrooktech.com — glenbrooktech.comglenbrooktech.com
  3. [3]JewelBox-100T — Glenbrook | Specs, Sourcing & Service | Waferpedia — waferpedia.comwaferpedia.com
  4. [4]JewelBox-100T | X-RAY Inspection | Machines and equipment — Amtest Ltd. — amtest.bgamtest.bg
  5. [5]Glenbrook JewelBox-100T family | Waferpedia — waferpedia.comwaferpedia.com
Was this page accurate?

Last updated Oct 6, 2026.

Compare with similar tools

View all →