The Bruker Dektak XT is a 2D contact stylus surface profiler used for step height, pitch, and surface roughness measurements. The Dektak XT has a vertical resolution of 1 Å (0.1 nm) and a stylus force range of 1 to 15 mg.[1]

BrukerDektak XT Stylus
No photo available yet

Performance

<5 Å, 1σ on 0.1 µm step[1]

Optics

1 Å max. (0.1 nm)[1]

What it is

The Bruker Dektak XT Stylus is a stylus profilometer used for surface profiling and metrology.[3]

The Bruker Dektak XT Stylus measures thin and thick film thickness, step height, surface topography, waviness, and roughness.[3]

How it works

The Bruker Dektak XT Stylus can take two-dimensional surface profile measurements and can also produce three-dimensional measurements and analyses with the 3D Mapping option.[3]

The Bruker Dektak XT Stylus has a stylus force range from 1 mg to 15 mg, supports 2.0 µm and 12.5 µm radius tips, and has a vertical resolution of 0.1 nm.[3]

Where it fits in the process flow

The Bruker Dektak XT Stylus is used to measure step height, surface profile, and roughness on soft or hard surfaces.[3]

Applications

The Bruker Dektak XT Stylus is used for thin-film and thick-film thickness measurement, step-height measurement, surface topography measurement, waviness measurement, and roughness measurement.[3]

The Bruker Dektak XT Stylus is used on soft films and hard films, and its selectable stylus force and tip sizes support different feature scales.[3]

What do the numbers mean?

Wafer handling1

Maximum Wafer Size
200 mm (8 in.)[1]
Accurate?

Optics & imaging2

Vertical Resolution
1 Å max. (0.1 nm)[1]
Accurate?
Vertical Resolution
0.1 nm[3]
Accurate?

Performance1

Step Height Repeatability
<5 Å, 1σ on 0.1 µm step[1]
Accurate?

Control & software1

Software
Vision 64[1]
Accurate?

Configuration & options15

Stylus Force Range
1 - 15 mg[1]
Accurate?
Tip Diameter
12.5 µm[1]
Accurate?
Vertical Range
1 mm (0.039 in.)[1]
Accurate?
Scan Length Range
55 mm (2 in.)[1]
Accurate?
Data Points Per Scan
120,000 maximum[1]
Accurate?
Sample X/Y Stage
Manual 100 mm X/Y, manual leveling[1]
Accurate?
Maximum Sample Thickness
50 mm (1.95 in.)[1]
Accurate?
Power Input
100 - 240 VAC, 110 VA max[2]
Accurate?
Stylus Type
Diamond-tipped[2]
Accurate?
Measurement Principle
Electromechanical, LVDT[2]
Accurate?
Optional Stylus Tips
2.0 µm and 12.5 µm radius[3]
Accurate?
Stylus Force Range
1 mg to 15 mg[3]
Accurate?
Stylus Tip Radii Available
2.0 μm and 12.5 μm[3]
Accurate?
Measurement Capability
2D and 3D surface profiling[3]
Accurate?
Vintage
2018[4]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What kind of measurements does the Bruker Dektak XT Stylus perform?

The Bruker Dektak XT Stylus measures thin and thick film thickness, surface topography, waviness, roughness, and step height.[3]

Can the Bruker Dektak XT Stylus make three-dimensional measurements?

The Bruker Dektak XT Stylus can produce three-dimensional measurements and analyses with the 3D Mapping option.[3]

What stylus tip sizes are available on this system?

The Bruker Dektak XT Stylus has 2.0 µm and 12.5 µm radius tips available.[3]

What is the stylus force range?

The Bruker Dektak XT Stylus has a stylus force range from 1 mg to 15 mg.[3]

What is the vertical resolution?

The Bruker Dektak XT Stylus has a vertical resolution of 0.1 nm.[3]

Not publicly documented

The following facts about the Dektak XT Stylus are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Dektak XT Stylus are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the Dektak XT Stylus are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the Dektak XT Stylus are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Dektak XT Stylus are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Dektak XT Stylus is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (4)Every fact above is drawn from these public sources
  1. [1]manualslib.com — manualslib.commanualslib.com
  2. [2]manualslib.com — manualslib.commanualslib.com
  3. [3]boisestate.edu — boisestate.eduboisestate.edu
  4. [4]Equipment inventory listing
Was this page accurate?

Last updated Oct 10, 2026.

Compare with similar tools

View all →