Waferpedia

Axcelis

NV 8250

Ion ImplantationAxcelis NV 8250 family
Research Quality: 40% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

NV 8250 — Inventory photo
Fig. 01NV 8250Inventory photo[1]

Power

208 VAC, 100 A, 50/60 Hz, 3 Phase[1]

Vacuum

TMP[1]

Gas delivery

AsH3 - SDS, PH3 - SDS, BF3 - SDS, Ar - HP[1]

What it is

The Axcelis NV 8250 is an implanter used for ion implantation in semiconductor manufacturing.[1][2]

What do the numbers mean?

Power & electrical1

Power Requirement
208 VAC, 100 A, 50/60 Hz, 3 Phase[1]
Accurate?

Vacuum & pumping6

Pump / Cryogenics
Source Pump: TMP; Beam Pump: TMP (2) and Cryo Pump (8" Torr, Non On-board); End Station Pump: 2 Cryo Pump (8" Torr, Non On-Board); Cryo Compressor: CTI 8500; Remote Disk Chiller[1]
Accurate?
Source Pump
TMP[1]
Accurate?
Beam Pump
TMP (2)[1]
Accurate?
Beam Pump
Cryo Pump (8" Torr, Non On-board)[1]
Accurate?
End Station Pump
2 Cryo Pump (8" Torr, Non On-Board)[1]
Accurate?
Cryo Compressor
CTI 8500[1]
Accurate?

Wafer handling3

Wafer Sizes
8 inch[1]
Accurate?
Electrostatic Chuck (ESC)
Yes[1]
Accurate?
Cassette Interface
Asyst Bolt-On SMIF (2), Cassette Stages (3), Automatic Flat/Notch Alignment, Programmable Flat Orient[1]
Accurate?

Gas & chemistry1

Gas Configuration
AsH3 - SDS, PH3 - SDS, BF3 - SDS, Ar - HP[1]
Accurate?

Control & software2

SECS II / GEM Interface
Yes[1]
Accurate?
Controller
Sun Sparc Station V, Application SW Ver. 4.3.2, Auto Start-Up & Computer Monitoring[1]
Accurate?

Configuration & options11

Backside[2]
Accurate?
Energy Range
0-250 keV[1]
Accurate?
Programmable Auto Tilt
0-75 degrees[1]
Accurate?
Single Stage Extraction
15-40 keV[1]
Accurate?
Ion Source Type
ELS[1]
Accurate?
Source Material Type
Moly[1]
Accurate?
Parallel Beam using Hybrid Scanning
Yes[1]
Accurate?
90 degrees Radially Indexed Dipole Magnet
Yes[1]
Accurate?
Signal Tower
Yes[1]
Accurate?
Energy Filter System Option
Yes[1]
Accurate?
Vintage
1999 (Backside)[2]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What replaced it?

Alternatives

Tools documented as functional equivalents — same process step and wafer size, from a different manufacturer. Each equivalence cites its source.

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Power Requirement208 VAC, 100 A, 50/60 Hz, 3 Phase[1]
  • Pump / CryogenicsSource Pump: TMP; Beam Pump: TMP (2) and Cryo Pump (8" Torr, Non On-board); End Station Pump: 2 Cryo Pump (8" Torr, Non On-Board); Cryo Compressor: CTI 8500; Remote Disk Chiller[1]
  • Gas ConfigurationAsH3 - SDS, PH3 - SDS, BF3 - SDS, Ar - HP[1]
  • Source PumpTMP[1]
  • Beam PumpTMP (2)[1]
  • Beam PumpCryo Pump (8" Torr, Non On-board)[1]
  • End Station Pump2 Cryo Pump (8" Torr, Non On-Board)[1]
  • Cryo CompressorCTI 8500[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the energy range of the NV 8250?

The energy range is 0 to 250 keV.[1]

What is the programmable auto tilt range?

The programmable auto tilt range is 0 to 75 degrees.[1]

Not publicly documented

The following facts about the NV 8250 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the NV 8250 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the NV 8250 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the NV 8250 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the NV 8250 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the NV 8250 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]inventory listing
Was this page accurate?

Last updated Oct 9, 2026.

Compare with similar tools