Waferpedia

Thermo Fisher

ARL 3460 Metals Analyzer

Precision OpticsProduced 1982–Thermo Fisher ARL 3460 Metals Analyzer family
Research Quality: 50% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Thermo Fisher ARL 3460 Metals Analyzer is a multi-channel optical emission spectrometer. The Thermo Fisher ARL 3460 Metals Analyzer was first launched in 1982. The Thermo Fisher ARL 3460 Metals Analyzer uses a one-meter Paschen-Runge vacuum polychromator.[1]

ARL 3460 Metals Analyzer — Inventory photo
Fig. 01ARL 3460 Metals AnalyzerInventory photo[2]

Produced

1982–

Power

Max 3.5 kVA[1]

Vacuum

Edwards vacuum (2022)[2]

Optics

130 to 780 nm[1]

What it is

The Thermo Fisher ARL 3460 Metals Analyzer is a spark optical emission spectrometer for metals analysis.[2][1]

How it works

The ARL 3460 uses a Paschen-Runge vacuum polychromator with up to sixty channels, a one meter focal length, and photomultiplier tube detection.[1][3]

The ARL 3460 uses a cast iron optical body with temperature control and an argon-flushed, water-cooled sample stand with closed-loop cooling.[1][3]

Where it fits in the process flow

The ARL 3460 is used for primary metal production, foundries, forges, mini-mills, casting operations, incoming material control, and metals quality control and research laboratories.[1][3]

The ARL 3460 is configured and calibrated before delivery so that it can be used as a turn-key instrument for sample analysis on the installation day.[1][3]

Applications

The ARL 3460 is used for fast metals analysis in production and laboratory settings.[1][3]

The ARL 3460 is used for nitrogen analysis in steels and oxygen analysis in steel and copper alloys.[1][3]

What do the numbers mean?

Power & electrical1

Electrical power
Max 3.5 kVA[1]
Accurate?

Vacuum & pumping3

Edwards vacuum (2022)[2]
Accurate?
Spectrometer design
Paschen-Runge vacuum polychromator made of special cast iron and temperature controlled to ±0.1° at 38°C[1]
Accurate?
Vacuum system
Edwards vacuum (2022)[2]
Accurate?

Optics & imaging3

Instrument type
Multi-channel optical emission spectrometer[1]
Accurate?
Detector type
Photomultiplier tube 28 mm, 10-stage side window tubes, fused quartz, glass or MgF2 windows[1]
Accurate?
Line selection range
130 to 780 nm[1]
Accurate?

Control & software2

Software
Windows 10[2]
Accurate?
Spectrometer control
ARL MMB 386 microprocessor utilizing CMOS technology with Status Measuring Card[1]
Accurate?

Dimensions & facilities3

Primary slit width
20 μm[1]
Accurate?
Overall dimensions
166.5 x 91 x 119 cm or 65 x 47 x 36 inches, including excitation stand[1]
Accurate?
Weight
450 kg or 992 lb approximately[1]
Accurate?

Configuration & options8

Focal length
1 m[1]
Accurate?
Maximum channels
60[1]
Accurate?
Secondary slit widths
20, 25, 37.5, 50, 75, 100, 150 μm[1]
Accurate?
Grating types
1080, 1667 or 2160 gr/mm[1]
Accurate?
Sample stand
Argon flushed, water-cooled table with self-contained, closed loop cooling system[1]
Accurate?
Programmable attenuators
Up to 24, available as an option[1]
Accurate?
Dynamic range
106:1[1]
Accurate?
Argon consumption
3.5 l/min during analysis, 0.35 l/min stand-by[1]
Accurate?

Vintage & configurations

  1. 1982Production start[1]

    The first model of the Thermo Scientific ARL 3460 was launched in 1982.

Documented models & variants

DesignationGenerationVintageChangesSource
ARL 3460 Advantage——Designed for foundries and metal processing industries dealing with cast iron, steel, aluminum, copper, nickel or cobalt products; factory calibrated for most accurate and uncompromising analytical performance.spekom.pl[3]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • ConfigurationEdwards vacuum (2022)[2]
  • Spectrometer designPaschen-Runge vacuum polychromator made of special cast iron and temperature controlled to ±0.1° at 38°C[1]
  • Electrical powerMax 3.5 kVA[1]
  • Vacuum systemEdwards vacuum (2022)[2]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What type of analyzer is the ARL 3460?

The ARL 3460 is a spark optical emission spectrometer for metals analysis.[2][1]

What metallurgical environments is the ARL 3460 used in?

The ARL 3460 is used in primary metal producing plants, foundries, forges, mini-mills, casting operations, incoming material control, and metals QC and R and D laboratories.[1][3]

What optical architecture does the ARL 3460 use?

The ARL 3460 uses a Paschen-Runge vacuum polychromator with a one meter focal length and up to sixty channels.[1][3]

Not publicly documented

The following facts about the ARL 3460 Metals Analyzer are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • The control-system platform and OS era of the ARL 3460 Metals Analyzer are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the ARL 3460 Metals Analyzer are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the ARL 3460 Metals Analyzer is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the ARL 3460 Metals Analyzer are on record.

    Answerable by: an OEM parts catalog or a service engineer

  • No publicly hosted manuals, SOPs, or datasheets for the ARL 3460 Metals Analyzer are on record.

    Answerable by: university cleanroom staff or an OEM application specialist

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]diecastmachinery.com — diecastmachinery.comdiecastmachinery.com
  2. [2]Inventory photo
  3. [3]spekom.pl — spekom.plspekom.pl
Was this page accurate?

Last updated Oct 12, 2026.

Compare with similar tools

View all →