Waferpedia

Pfeiffer

Adixen ASM 182 TD+ Helium Leak Detector

Produced –2025Pfeiffer Adixen family
Research Quality: 50% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Pfeiffer Adixen ASM 182 TD+ is a helium leak detector. The Pfeiffer Adixen ASM 182 TD+ supports vacuum and sniffing leak detection. The Pfeiffer Adixen ASM 182 TD+ has a 4.4 l/s helium pumping speed.[1][2]

Adixen ASM 182 TD+ Helium Leak Detector — Inventory photo
Fig. 01Adixen ASM 182 TD+ Helium Leak DetectorInventory photo[3]

Produced

–2025

Power

110–130 V, 50/60 Hz[2]

Vacuum

Pfeiffer Vacuum[1]

What it is

The Pfeiffer Adixen ASM 182 TD+ is a helium leak detector.[4]

How it works

The ASM 182 TD+ uses helium as the tracer gas for leak detection.[2]

The ASM 182 TD+ supports vacuum leak detection and sniffing leak detection.[2]

Where it fits in the process flow

The ASM 182 TD+ is used for quality control and maintenance of semiconductor processing systems.[2]

The ASM 182 TD+ is also used for quality control of vacuum components.[2]

Applications

The ASM 182 TD+ is used in semiconductor processing systems.[2]

The ASM 182 TD+ is used for quality control of vacuum components.[2]

The ASM 182 TD+ is used for blister testing in the pharmaceutical industry.[2]

What do the numbers mean?

Power & electrical1

Supply
110–130 V, 50/60 Hz[2]
Accurate?

Vacuum & pumping7

Manufacturer
Pfeiffer Vacuum[1]
Accurate?
Detection method
Vacuum and Sniffing Leak Detection[2]
Accurate?
Pumping speed for He
4.4 l/s[2]
Accurate?
Backing pump capacity
25 m^3/h[2]
Accurate?
Backing pump
Oil-Free Backing Pump[2]
Accurate?
Minimum detectable leak rate for helium (vacuum leak detection)
5 x 10^-13 Pa m3/s[2]
Accurate?
Test method
Vacuum and Sniffing Leak Detection[2]
Accurate?

Control & software1

User interface
Basic User Interface[2]
Accurate?

Dimensions & facilities2

Dimensions (L x W x H)
601 x 487 x 456 mm[2]
Accurate?
Weight
88 kg[2]
Accurate?

Configuration & options12

P/N
D 70 RTS 0 PB 710[3]
Accurate?
Model
ASM 182 TD+[3]
Accurate?
P/N
D10RSS0PB710[1]
Accurate?
Flange model (inlet)
DN 40 ISO-KF[2]
Accurate?
Language
English[2]
Accurate?
Mains cable
US power cable[2]
Accurate?
Minimum detectable leak rate for helium (sniffing leak detection)
1 x 10^-8 Pa m3/s[2]
Accurate?
Noise level
65 dB(A)[2]
Accurate?
Power consumption max.
1500 W[2]
Accurate?
Start-up time with calibration
< 5.5 min[2]
Accurate?
Start-up time without calibration
< 4 min[2]
Accurate?
Type
High Performance - Compact[2]
Accurate?

Vintage & configurations

  1. 2025-09-12Production end[1]

    One source identifies the item as discontinued.

Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • ManufacturerPfeiffer Vacuum[1]
  • Detection methodVacuum and Sniffing Leak Detection[2]
  • Pumping speed for He4.4 l/s[2]
  • Backing pump capacity25 m^3/h[2]
  • Backing pumpOil-Free Backing Pump[2]
  • Supply110–130 V, 50/60 Hz[2]
  • Minimum detectable leak rate for helium (vacuum leak detection)5 x 10^-13 Pa m3/s[2]
  • Test methodVacuum and Sniffing Leak Detection[2]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What leak-detection methods does the ASM 182 TD+ support?

The ASM 182 TD+ supports vacuum leak detection and sniffing leak detection.[2]

What tracer gas does the ASM 182 TD+ use?

The ASM 182 TD+ uses helium as the detectable gas.[2]

What semiconductor-related work is the ASM 182 TD+ used for?

The ASM 182 TD+ is used extensively in quality control and maintenance of semiconductor processing systems.[2]

Is a pharmaceutical application named for the ASM 182 TD+?

The ASM 182 TD+ is used as a blister-testing appliance within the pharmaceutical industry.[2]

Not publicly documented

The following facts about the Adixen ASM 182 TD+ Helium Leak Detector are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented variants, configuration options, or revision breakpoints of the Adixen ASM 182 TD+ Helium Leak Detector are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the Adixen ASM 182 TD+ Helium Leak Detector are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Adixen ASM 182 TD+ Helium Leak Detector are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Adixen ASM 182 TD+ Helium Leak Detector is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the Adixen ASM 182 TD+ Helium Leak Detector are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (4)Every fact above is drawn from these public sources
  1. [1]ajvs.com — ajvs.comajvs.com
  2. [2]ajvs.com — ajvs.comajvs.com
  3. [3]Inventory photo
  4. [4]Adixen ASM 182 TD+ Helium Leak Detector — Pfeiffer | Specs, Sourcing & Service | Waferpedia — waferpedia.comwaferpedia.com
Was this page accurate?

Last updated Oct 10, 2026.

Compare with similar tools

View all →