Waferpedia

Exatron

PET2

Test & ProbeIntroduced Produced 1997–Exatron PET2 family
Research Quality: 60% complete

Exatron PET2 is a semi-automated prototype engineering test fixture. Exatron PET2 provides device placement, alignment, and test head clamping. Exatron PET2 is intended for tray-borne devices such as QFPs, PQFPs, and TSOPs.[1][2]

PET2 — web.archive.org
Fig. 01PET2web.archive.org[1]

Produced

1997–

Vacuum

Clean, dry air at 80 PSI/5 CFM[1]

What it is

The Exatron PET2 is a semi-automated prototype engineering test fixture for tray-borne devices. The PET2 belongs to Exatron's test and probe handler family.[1][2]

The PET2 is a handler solution for devices that are strictly tray-borne. The PET2 is part of Exatron's concept of single tooling from benchtop to production floor.[1]

How it works

The PET2 accepts manual loading or unloading, and an air wand can assist handling. The device under test is placed in a machined face plate, held by vacuum, mechanically aligned by its body, and electrically aligned by docking the face plate to a corresponding plate on a printed circuit board.[1]

The PET2 rotates the device into the test site and sends a start test pulse to the tester after positive positioning. The PET2 returns the device to the operator after a pass or fail signal, or drops devices into reject bins built into the unit.[1]

Where it fits in the process flow

The PET2 sits between device preparation and electrical test. The PET2 is intended for engineering use when a test programme is being developed for a new device, and it supports high speed testing and device characterization.[1]

The PET2 uses the same handler communication protocols as Exatron's other handlers. The PET2 test site tooling and contactors can be mounted directly to other Exatron plunge-to-board handlers.[1]

Applications

The PET2 is used for device characterization and high speed testing. The PET2 is intended for tray-borne packages such as QFPs, PQFPs, and TSOPs.[1][2]

  • device characterization
  • high speed testing
  • development of a test programme for a new device

What do the numbers mean?

Power & electrical1

electrical alignment
face plate is placed onto a corresponding docking plate mounted on a printed circuit board[1]
Accurate?

Vacuum & pumping3

device holding
vacuum holds the DUT in a precisely machined Face Plate[1]
Accurate?
power and air requirements
110/220 VAC; clean, dry air at 80 PSI/5 CFM[1]
Accurate?
Air requirement
Clean, dry air at 80 PSI/5 CFM[1]
Accurate?

Performance2

alignment method
device is mechanically aligned by its body, not by its leads[1]
Accurate?
Functions
Device placement, alignment, and test head clamping[1]
Accurate?

Configuration & options7

device loading
loaded and unloaded by hand or with an air wand[1]
Accurate?
output handling
returns the device to the operator after pass/fail, or drops devices into one of two small reject bins[1]
Accurate?
output tube support
can accommodate a two-tube mount for output tubes[1]
Accurate?
mounting options
table-top mounted, mounted directly to the test head, or mounted on a FRED (Free Rolling Exatron Dolly)[1]
Accurate?
Device type
Semi-automated prototype engineering test fixture[1]
Accurate?
Supported package types
Tray-borne devices such as QFPs, PQFPs, and TSOPs[1]
Accurate?
Power requirement
110/220 VAC[1]
Accurate?

Vintage & configurations

  1. 1997Production start[2]

    PET2 introduced in 1997.

Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • device holdingvacuum holds the DUT in a precisely machined Face Plate[1]
  • electrical alignmentface plate is placed onto a corresponding docking plate mounted on a printed circuit board[1]
  • power and air requirements110/220 VAC; clean, dry air at 80 PSI/5 CFM[1]
  • Air requirementClean, dry air at 80 PSI/5 CFM[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What package types does the PET2 handle?

The PET2 is Exatron's handler solution for devices that are strictly tray-borne, including QFPs, PQFPs, and TSOPs.[1][2]

What does the PET2 do during test handling?

The PET2 provides device placement, alignment, and test head clamping for device characterization and high speed testing.[1]

How is the device aligned in the PET2?

The PET2 mechanically aligns the device by its body rather than by its leads, and it electrically aligns the device by docking the face plate onto a corresponding plate on a printed circuit board.[1]

How is a device loaded and unloaded?

The operator loads and unloads the PET2 by hand or with an air wand.[1]

Can the PET2 be used with other Exatron handlers?

The PET2 test site tooling and contactors can be mounted directly to other Exatron plunge-to-board handlers, and the handler-tester communication protocols are the same as those used by Exatron's other handlers.[1]

Not publicly documented

The following facts about the PET2 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented variants, configuration options, or revision breakpoints of the PET2 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the PET2 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the PET2 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the PET2 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the PET2 are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]web.archive.org — web.archive.orgweb.archive.org
  2. [2]waferpedia.com — waferpedia.comwaferpedia.com