Waferpedia

Edwards

IQDP 40

Edwards IQDP 40 family
Research Quality: 30% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

EdwardsIQDP 40
No photo available yet

Power

44 m³ h⁻¹[1]

Vacuum

186 kg[1]

How it works

The iQDP 40 pump uses pairs of intermeshing rotors of different profiles mounted on common shafts, held in phase by oil-lubricated timing gears. The timing gears and adjacent double-row angular-contact ball bearings are oil lubricated. The pump has an indirect cooling system and the pump motor is water cooled. A Gas Module introduces purge gas into the pump; three types of Gas Module are available for light, medium, and harsh duty processes. An optional Pump Display Module allows manual control of the system.[4][1]

What do the numbers mean?

Power & electrical7

Typical peak pumping speed (50 Hz)
44 m³ h⁻¹[1]
Accurate?
Typical peak pumping speed (60 Hz)
55 m³ h⁻¹[1]
Accurate?
Displacement (swept volume) at 50 Hz
52.0 m³ h⁻¹[1]
Accurate?
Displacement (swept volume) at 60 Hz
62.4 m³ h⁻¹[1]
Accurate?
Ultimate vacuum (with shaft-seals purge, 50 Hz)
5 × 10⁻² mbar[1]
Accurate?
Motor power
2.2 kW[2]
Accurate?
Electrical supply
3-phase, 208-230/380-415 V, 50/60 Hz[3]
Accurate?

Vacuum & pumping2

Mass (pump only)
186 kg[1]
Accurate?
Exhaust connection
KF40[3]
Accurate?

Configuration & options2

Noise level
< 70 dB(A)[1]
Accurate?
Inlet connection
ISO40 bolted[3]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
QDP40——Earlier production model with serial numbers 13940 and higher; iQDP40 has serial numbers 11210 and higher.scribd.com[2]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Typical peak pumping speed (50 Hz)44 m³ h⁻¹[1]
  • Typical peak pumping speed (60 Hz)55 m³ h⁻¹[1]
  • Displacement (swept volume) at 50 Hz52.0 m³ h⁻¹[1]
  • Displacement (swept volume) at 60 Hz62.4 m³ h⁻¹[1]
  • Ultimate vacuum (with shaft-seals purge, 50 Hz)5 × 10⁻² mbar[1]
  • Mass (pump only)186 kg[1]
  • Motor power2.2 kW[2]
  • Exhaust connectionKF40[3]
  • Electrical supply3-phase, 208-230/380-415 V, 50/60 Hz[3]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What are the inlet and exhaust connections?

The inlet connection is ISO 40 bolted and the exhaust connection is KF 40.[3]

What pumping speed does the pump deliver?

The pumping speed is 32.37 CFM at 60 Hz.[3]

How many stages does the IQDP 40 have?

The IQDP 40 is a four-stage positive displacement rotary pump.[4]

What types of gas modules are available?

Three types of Gas Module are available for the IQDP 40: for light, medium, and harsh duty processes.[4][1]

Not publicly documented

The following facts about the IQDP 40 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the IQDP 40 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the IQDP 40 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the IQDP 40 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the IQDP 40 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the IQDP 40 are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (5)Every fact above is drawn from these public sources
  1. [1]idealvac.com — idealvac.comidealvac.com
  2. [2]scribd.com — scribd.comscribd.com
  3. [3]provac.com — provac.comprovac.com
  4. [4]Fully Refurbished Edwards Vacuum iQDP 40 Dry Vacuum Pump, Semiconductor Pump, A53240880, Edwards Vacuum iQDP-40, Edwards Vacuum iQDP40 — ajvs.comajvs.com
  5. [5]Equipment inventory listing
Was this page accurate?

Last updated Sep 24, 2026.

Compare with similar tools

View all →