The Denton Vacuum DV-23 is a two-position thermocouple controller. The Denton Vacuum DV-23 provides redundant measurement of foreline pressure. The Denton Vacuum DV-23 provides redundant measurement of mechanical pump performance.[1][2][3]

Denton VacuumDV-23
No photo available yet

What it is

The Denton Vacuum DV-23 is a two position thermocouple controller used with a vacuum coating system to provide redundant measurement of foreline pressure and mechanical pump performance.[1][2][3]

How it works

The systems associated with the DV-23 use thermocouple and ionization gauge readings on the control screen, and the computer can manage gauge operation and interlocks automatically.[1][2][3]

The DV-23 provides a second thermocouple channel for foreline monitoring, which supports observation of the roughing side of the vacuum system during pumpdown and pump operation.[1][2][3]

What can it run?

Process applications and technology nodes documented for this tool.

  • foreline pressure measurement
  • mechanical pump performance measurement

What do the numbers mean?

Vacuum & pumping3

function
provides redundant measurement of foreline pressure and mechanical pump performance[2]
Accurate?
OEM
Denton Vacuum[2]
Accurate?
Function
redundant measurement of foreline pressure and mechanical pump performance[1]
Accurate?

Control & software2

device type
two position thermocouple controller[2]
Accurate?
Controller type
two-position thermocouple controller[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • functionprovides redundant measurement of foreline pressure and mechanical pump performance[2]
  • OEMDenton Vacuum[2]
  • Functionredundant measurement of foreline pressure and mechanical pump performance[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What measurement role does the DV-23 serve in the coating system?

The DV-23 provides redundant measurement of foreline pressure and mechanical pump performance.[1][2][3]

What type of system uses the DV-23?

The DV-23 is used with ophthalmic coating systems.[1][2][3]

What other vacuum-system functions are automated in the associated coating tools?

The associated coating tools include Autopump, Autovent, and Autoregen programs for automatic pumping and gauge control.[1][2][3]

Not publicly documented

The following facts about the DV-23 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the DV-23 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the DV-23 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the DV-23 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the DV-23 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the DV-23 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]web.archive.org — web.archive.orgweb.archive.org
  2. [2]web.archive.org — web.archive.orgweb.archive.org
  3. [3]Denton Vacuum Integrity-50 Fully Automated Ophthalmic Coating System — web.archive.orgweb.archive.org
Was this page accurate?

Last updated Oct 4, 2026.

Compare with similar tools

View all →