Waferpedia

Balzers

Pfeiffer TPU 240 Turbomolecular

Balzers Pfeiffer TPU family
Research Quality: 30% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

Pfeiffer TPU 240 Turbomolecular — Inventory photo
Fig. 01Pfeiffer TPU 240 TurbomolecularInventory photo[1]

What is it?

Applications

The TPU 240 is used in ultra-high-vacuum R&D chamber assemblies, surface science analysis equipment (XPS, Auger, SIMS), electron microscopy (SEM, TEM), cryogenic vessel evacuation, thin-film deposition, mass spectrometry, freeze drying, degassing, incandescent lamp manufacturing, electronic tubes, space simulation, and nuclear, plasma, and high-energy physics.[2][3]

What do the numbers mean?

Vacuum & pumping12

High-Vacuum Inlet Flange
DN 100 CF-F (6" ConFlat Fixed)[2]
Accurate?
Foreline / Exhaust Flange
DN 25 ISO-KF (NW25)[2]
Accurate?
Pumping Speed (N2)
230 L/s[2]
Accurate?
Pumping Speed (He)
240 L/s[2]
Accurate?
Pumping Speed (H2)
210 L/s[2]
Accurate?
Ultimate Base Pressure
≤ 1 × 10^-11 mbar (≤ 7.5 × 10^-12 Torr)[2]
Accurate?
Equipment type
Turbomolecular pump[1]
Accurate?
Manufacturer
Pfeiffer Vacuum (Germany)[2]
Accurate?
Type of product
turbo pump[3]
Accurate?
Exhaust
KF25[3]
Accurate?
Pumping speed
230 l/s (N2)[3]
Accurate?
Recommended backing pump
DUO 016B[3]
Accurate?

Control & software1

Recommended controller
TCP-121, TCP-380[3]
Accurate?

Dimensions & facilities2

Weight
9.0 kg (19.8 lbs)[2]
Accurate?
Weight
20 lbs[3]
Accurate?

Configuration & options21

Volume Flow Rate
230[1]
Accurate?
Manufacturer
Balzers Pfeiffer[1]
Accurate?
Model
TPU 240[1]
Accurate?
Part Number
PMP01330A[2]
Accurate?
Condition
Refurbished[2]
Accurate?
Compression Ratio (N2)
1 × 10^8[2]
Accurate?
Nominal Rotational Speed
60,000 RPM[2]
Accurate?
Ramp-Up / Start Time
≈ 1 to 3 minutes[2]
Accurate?
Cooling Method
Natural Convection / Forced Air / Water-Cooling (15 L/h at 15 °C)[2]
Accurate?
Lubricant Charge
8 cm^3 F4 / F5 Operating Fluid Wick Compatible Controllers[2]
Accurate?
Part number
PM P01 330 A (PMP01330A)[2]
Accurate?
Lubricant charge
8 cm3 F4 / F5 operating fluid wick compatible[2]
Accurate?
Compatible controllers
Pfeiffer TCP 121 / TCP 380 / TCP 300 series[2]
Accurate?
Make
Balzers Pfeiffer[1]
Accurate?
Lubricant charge
8 cm3 F4 / F5 operating fluid[2]
Accurate?
Manufacturer
Pfeiffer[3]
Accurate?
Condition
rebuilt[3]
Accurate?
Part number
PMP01330B[3]
Accurate?
Inlet
6" conflat[3]
Accurate?
Vent valve
fixed[3]
Accurate?
Compression ratio
10^8 (N2)[3]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • High-Vacuum Inlet FlangeDN 100 CF-F (6" ConFlat Fixed)[2]
  • Foreline / Exhaust FlangeDN 25 ISO-KF (NW25)[2]
  • Pumping Speed (N2)230 L/s[2]
  • Pumping Speed (He)240 L/s[2]
  • Pumping Speed (H2)210 L/s[2]
  • Ultimate Base Pressure≤ 1 × 10^-11 mbar (≤ 7.5 × 10^-12 Torr)[2]
  • Equipment typeTurbomolecular pump[1]
  • ManufacturerPfeiffer Vacuum (Germany)[2]
  • Type of productturbo pump[3]
  • ExhaustKF25[3]
  • Pumping speed230 l/s (N2)[3]
  • Recommended backing pumpDUO 016B[3]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Not publicly documented

The following facts about the Pfeiffer TPU 240 Turbomolecular are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Pfeiffer TPU 240 Turbomolecular are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the Pfeiffer TPU 240 Turbomolecular are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the Pfeiffer TPU 240 Turbomolecular are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Pfeiffer TPU 240 Turbomolecular are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Pfeiffer TPU 240 Turbomolecular is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]labvac.com — labvac.comlabvac.com
  3. [3]provac.com — provac.comprovac.com
Was this page accurate?

Last updated Oct 11, 2026.

Compare with similar tools

View all →