Applied Materials 0010-18024 Pyrometer Assembly, Axcelis 9355 UPS, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
9355 UPSAxcelis
OEMApplied MaterialsAxcelis
CategoryMetrology & InspectionMetrology & Inspection
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyApplied Materials 0010-18024 Pyrometer AssemblyAxcelis 9355 UPS
Cited variants—
  • 9355 10 kVA with 32-Battery (2-high)[1]
  • 9355 10 kVA with 64-Battery (3-high)[1]
  • 9355 15 kVA with 32-Battery (2-high)[1]
  • 9355 15 kVA with 64-Battery (3-high)[1]
  • 9355 20 kVA with Internal Batteries[1]
  • 9355 30 kVA with Internal Batteries[1]
  • 9355 10 kVA with Input Isolation Transformer (3-high)[1]
  • 9355 15 kVA with Input Isolation Transformer (3-high)[1]
Specifications
ConfigurationCapable of working on Applied Materials Radiance[2]Defective batteries[3]
Power—15kVA/ 13.5kW[3]
Make—Axcelis[3]
Model—9355[3]
Product type—AC Back-up Power (UPS)[4]
Axcelis 9355 UPS rating—15 kVA / 13.5 kW[3]
Power rating—10-30 kVA[1]
Topology—Double conversion[5]
Voltage—208/220/400/480/600 Vac three phase[1]
Frequency—50/60 Hz[1]
Output power factor—0.9[1]
Input power factor—>0.99 typical (10-15 kVA); 0.99 typical (20-30 kVA)[5]
Input current distortion—5% THD[5]
Internal batteries—Standard on all configurations[1]
Integrated power distribution module—On-board, plug-and-play power distribution module[1]
Maintenance bypass switch—Integrated maintenance bypass switch[1]
Paralleling—Up to four 9355 UPS units for capacity or redundancy using Powerware Hot Sync technology[1]
Scalability—10 kVA and 20 kVA configurations can be upgraded to 15 kVA and 30 kVA, respectively, without additional hardware[1]
Battery type—9 Ah, sealed, lead-acid, maintenance-free[5]
Battery management—Microprocessor-controlled ABM technology with three-stage charging[1]
Battery replacement—Field-replaceable batteries[1]
Display—Four-button graphical LCD[1]
Communication ports—(1) RS-232, (1) relay contact, (1) REPO, (2) environmental input[5]
Operating temperature—50-104°F (10-40°C); 45°C with 7.5% derating[5]
Overload capability—150% for 5 s / 125% for 1 min (online); 110% for 10 min[5]
Safety certifications—UL1778 5th Edition, CSA C22.2 No. 107.3-14, NOM-NYCE[5]
Emergency lighting models—UL924 Emergency Lighting models available[4]
OEM—Axcelis[3]
Phase—Three-phase[1]
Parallel capability—Up to four units can be paralleled[1]

Plan your fab

Building a Metrology & Inspection process? Get a complete equipment list.

Open the fab equipment planner →
Sources (5)Every fact above is drawn from these public sources
  1. [1]eatonguard.comeatonguard.com
  2. [2]inventory listing
  3. [3]inventory listing
  4. [4]hmcragg.comhmcragg.com