Comparison ledger
ABM -407B-2-S-CE-S293 Robot, Agilent 8566 B Spectrum Analyzer, side by side. Every value shown is drawn from the cited encyclopedia entries.
| Attribute | 8566 B Spectrum AnalyzerAgilent | |
|---|---|---|
| OEM | ABM | Agilent |
| Category | — | — |
| Wafer size | — | — |
| Process node | — | — |
| Introduced | — | — |
| Production run | — | — |
| Lifecycle | — | — |
| Lifecycle milestones | — | — |
| Control system | — | — |
| Generation | — | — |
| Family | ABM -407B-2-S-CE-S293 Robot | Agilent 85xx |
| Cited variants | — | |
| Specifications | ||
| Model | ABM-407B-2-S-CE-S293[2] | 8566B Spectrum Analyzer[3] |
| Description | ROBOT[2] | — |
| Refurbished RTP RTA | AG Associates 4100, 4108, 8108, 8800, 8800i,210, 310, 410, 610, 610I, MPT RTP-600S, 800S, RTP-3000[2] | — |
| KLA-Tencor Spare Parts and Service | RS-35C,RS-55,RS-75,RS-100,UV-1050,UV-1080,UV-1250,UV-1280,ASET F5 / F5X,AIT Systems,HRP-220 Stylus Profiler[2] | — |
| Refurbished Isotropic Plasma Etcher | Matrix, Tegal, Lam Research, Branson/IPC, PlasmaTherm[2] | — |
| Refurbished PECVD, ALD Equipment | Cambridge, Oxford PlasmaLab , Plasma-Therm, STS/SPTS, AMAT[2] | — |
| Refurbished Mask Aligner | Canon Neutronix PLA501/545, Suss MA200CC, MA8BA8 GEN3, MA8BA8 GEN2, MA8BA8, MA200E[2] | — |
| Refurbished Bonding | SUSS SB6E, SUSS SB8E, EVG 620 BA, EVG EV501, West Bond 7200AR 7400A[2] | — |
| Refurbished Wafer Prober | Electroglas EG 4090u+, EG 4090, EG 2001X, EG 1034X, Cascade PS-21[2] | — |
| Configuration | — | with Display[3] |
| Instrument type | — | Spectrum analyzer[3] |
| Frequency range | — | 100 Hz to 22 GHz[1] |
| Preselected tuning range | — | 2 to 22 GHz[4] |
| Measurement range | — | -135 dBm to +30 dBm[1] |
| Input | — | dc-coupled input[1] |
| Instrument composition | — | 85662A Display Section and 85660B RF Section[4] |
| Support status | — | Agilent no longer sells or supports this product[5] |
| Power requirements | — | 50 to 60 Hz; 100, 200, 120, 220, or 240 V (+5%, -10%); approximately 650 VA (40 VA in standby)[1] |
| Display technology | — | Cathode ray tube with post deflection accelerator, aluminized P31 phosphor, electrostatic focus and deflection[1] |
| OEM | — | Agilent[3] |
| Low-frequency band | — | 100 Hz to 2.5 GHz[4] |
| Microwave band | — | 2 to 22 GHz[4] |
| Instrument sections | — | 85662A Display Section and 85660B RF Section[4] |
| Frequency span | — | 0 Hz, 100 Hz to 22 GHz over 10 division CRT horizontal axis; variable in approximately 1% increments[1] |
| Resolution bandwidth | — | 10 Hz to 3 MHz in a 1, 3, 10 sequence[1] |
| Amplitude measurement range | — | +30 to -135 dBm[1] |
| Reference level range, log | — | +30.0 to -99.9 dBm or equivalent in dBmV, dBμV, volts; expandable to +60.0 dBm to -119.9 dBm[1] |
| RF input | — | 100 Hz to 22 GHz, precision type-N female connector, dc-coupled[1] |
| Maximum input level, continuous power | — | +30 dBm from 50 ohm source[1] |
| Input attenuator | — | 0 to 70 dB in 10 dB steps[1] |
| Display outputs | — | X, Y, and Z outputs for auxiliary CRT displays; X and Y 1 V for full deflection; Z 0 to 1 V intensity modulation; BLANK TTL level > 2.4 V[1] |
| Recorder outputs | — | Horizontal sweep output, video output, and penlift output for X-Y recorders[1] |
| Frequency reference output | — | 10.000 MHz, 0 dBm, 50 ohm output impedance[1] |
| Sweep and tune output | — | -1 V/GHz of tuned frequency ±(2% + 10 mV), 10 kohm impedance[1] |
| Remote operation | — | GP-IB; all analyzer control settings except video trigger level, focus, align, intensity, freq zero, amptd cal, and line power are remotely programmable[1] |